Workplace health, safety, risk and emergency training · In person and onlinePartner program1800 231 173
Orana Skills Centre
Home / Documents & Templates / CCV packs / Mine Gases and Ventilation
Documents & Templates

Mine Gases and Ventilation Critical Control Verification Pack

Critical control verification (CCV) checklists for mine gases and ventilation: one four-page CCV form for each of the 13 critical controls that stop the unwanted event, exposure to or ignition of mine gases, or loss of ventilation, underground, or limit the harm when it happens, with the bowtie, a verification schedule and a guide.

  • HazardMine gases, coal dust and diesel exhaust in underground air
  • Unwanted eventExposure to or ignition of mine gases, or loss of ventilation, underground
  • Critical controls13: 9 preventing, 4 mitigating
  • FormsOne four-page CCV form per control, the bowtie, a CCV schedule and a guide
  • Task or hazardManaging critical risks
  • JurisdictionNational: check licences and notifications with your regulator
  • FormatsWord and Excel, editable, with PDF copies
  • Version1.0 · 7.4 MB ZIP

What is this pack?

The Mine Gases and Ventilation Critical Control Verification Pack is a set of editable critical control verification (CCV) checklists for mine gas and ventilation risks, for WHS advisers, managers, supervisors and control owners. It covers 13 critical controls (9 preventing, 4 mitigating) for the unwanted event: exposure to or ignition of mine gases, or loss of ventilation, underground. It includes 13 four-page CCV forms in Word and PDF, one for each critical control; the Mine Gases and Ventilation Bowtie on one page; the CCV schedule in Word, PDF and Excel; and the guide How to Use These CCVs. It draws on the model Code of Practice How to manage work health and safety risks, cited by title. It supports verification; it is not legal advice.

The 13 critical controls

  1. CCV-01 Ventilation delivers the designed air to every working place (preventing)
  2. CCV-02 Main and booster fans running, monitored and alarmed (preventing)
  3. CCV-03 Auxiliary fans and ducting delivering air to the face (preventing)
  4. CCV-04 Ventilation doors, stoppings and regulators intact and set (preventing)
  5. CCV-05 Fixed gas monitoring with alarms and power trips acted on (preventing)
  6. CCV-06 Personal and portable gas detectors carried, tested and used (preventing)
  7. CCV-07 Gas drainage working where the seam or ground requires it (preventing)
  8. CCV-08 Ignition sources controlled where flammable gas or coal dust may be present (preventing)
  9. CCV-09 Re-entry after firing or a fan stoppage only after gas testing (preventing)
  10. CCV-10 Stone dust and explosion barriers maintained in coal mines (mitigating)
  11. CCV-11 Self-rescuers carried, in service and people able to use them (mitigating)
  12. CCV-12 Refuge chambers and fresh air bases ready (mitigating)
  13. CCV-13 Gas trigger action response, evacuation and mine rescue (mitigating)

About this pack

Most workplaces have controls for mine gases and ventilation: main and auxiliary fans, ventilation doors and stoppings, fixed and personal gas detectors, re-entry gas testing and self-rescuers. The question is whether they are working today. A critical control verification (CCV) is the proof: a planned check, in the field, that a control that matters most is in place, in good condition, working as designed, used properly and not bypassed.

This pack gives you one CCV form for each of 13 critical controls (9 preventing, 4 mitigating). Each form shows where the control sits on the bowtie, what it must achieve, how it fails, and a checklist grouped by those five checks and then the records. The last page has prompts for talking to the people who use the control.

Every item is Pass or Fail; Non-conformance is kept for administrative items such as records and training dates, and its box is greyed out on the rest. A Fail stops the work that relies on the control and is escalated as a high potential incident. The download holds 13 four-page CCV forms in Word and PDF, one for each critical control; the Mine Gases and Ventilation Bowtie on one page; the CCV schedule in Word, PDF and Excel; and the guide How to Use These CCVs.

Where it applies: Underground mines, metalliferous and coal, and the shafts, declines and drives that serve them, wherever people work in air that depends on mechanical ventilation, or where methane, carbon monoxide, hydrogen sulphide, low oxygen, blasting fumes, diesel exhaust or coal dust may be present. In Australia, mining has its own work health and safety laws: each state and territory has laws or regulations for mines and quarries, and your site's principal hazard management plans and trigger action response plans come first. The pack gives no design values: every limit is a placeholder for your site's own design criteria and standards.

Where it applies: Underground mines, metalliferous and coal, and the shafts, declines and drives that serve them, wherever people work in air that depends on mechanical ventilation, or where methane, carbon monoxide, hydrogen sulphide, low oxygen, blasting fumes, diesel exhaust or coal dust may be present. Your site's ventilation principal hazard management plan, gas management plans and trigger action response plans come first: use these forms to verify the controls they set.

What it helps you do

  • Prove, not assume, that the 13 critical controls for mine gases and ventilation are in place and working
  • Score each control the same way every time: Pass, Fail, or Non-conformance for administrative items only
  • Act at once on a Fail, and close every Non-conformance with an owner and a date
  • Hear from the people who use each control where it is skipped or hard to use
  • Report CCV results as a leading indicator, alongside incident data

Each checklist is grouped by

  • It exists: it is there, at this place, for this work, today
  • It is in place and in good condition
  • It functions as designed
  • It is being used properly
  • It is not being bypassed or failing silently
  • Records and administration
Goes with this pack 1 related product

Save with the library

The Critical Control Verification Library holds all 17 CCV packs for $999 incl. GST, $1,534 less than buying them separately$908.18 AUD (GST-free outside Australia), $1,394.55 less than buying them separately.

The critical controls

Each has its own four-page CCV form. Preventing controls sit on the threat lines of the bowtie and stop the unwanted event; mitigating controls sit on the consequence lines and limit the harm. A control on both sides is one control, verified for both roles.

CCVCritical controlTypeSits onChecklist items
CCV-01Ventilation delivers the designed air to every working place
Deliver at least the air quantity and velocity in [Ventilation design] to every working place and diesel unit, proven by regular ventilation surveys, with any shortfall acted on before work goes on.
PreventingT110 (2 administrative)
CCV-02Main and booster fans running, monitored and alarmed
Keep the main and booster fans running at their set duty, monitored continuously, with an alarm on stoppage or a drop in performance to a person who acts, and a planned response to a stoppage.
PreventingT210 (2 administrative)
CCV-03Auxiliary fans and ducting delivering air to the face
Ventilate every dead-end heading with an auxiliary fan and ducting that delivers [Ventilation design] at the face, with the duct within the maximum distance of the face, the fan placed so it does not recirculate air, and the fan running whenever people are in the heading.
PreventingT1, T210 (2 administrative)
CCV-04Ventilation doors, stoppings and regulators intact and set
Keep the air going where the design sends it, with ventilation doors closed except for passage, stoppings intact and sealed, and regulators set as the ventilation officer sets them.
PreventingT210 (2 administrative)
CCV-05Fixed gas monitoring with alarms and power trips acted on
Monitor gases continuously at the locations the gas management plan sets, with alarms, and automatic power trips where required, at [Gas trigger levels], so that a build-up is acted on and electrical power is removed before flammable gas reaches an ignition source.
PreventingT3, T410 (2 administrative)
CCV-06Personal and portable gas detectors carried, tested and used
Make sure the people the site requires carry a calibrated, bump tested gas detector for the gases that may be present, use it to test the air before and while working, and act on every alarm at [Gas trigger levels].
PreventingT3, T510 (2 administrative)
CCV-07Gas drainage working where the seam or ground requires it
Where the coal or rock gives off gas faster than ventilation can safely dilute it, remove the gas before and during mining with the gas drainage the gas management plan sets, keeping it working, effective and monitored.
PreventingT310 (2 administrative)
CCV-08Ignition sources controlled where flammable gas or coal dust may be present
Keep ignition sources away from flammable gas and coal dust: explosion-protected equipment in [Hazardous zones], maintained so its protection is intact, hot work and other sources of sparks or heat only under permit with gas testing, and no prohibited items taken underground where the site bans them.
PreventingT410 (3 administrative)
CCV-09Re-entry after firing or a fan stoppage only after gas testing
Keep everyone out after firing until the clearance time has passed and the air has been tested, and after a fan stoppage until ventilation is restored and the air tested, as [Re-entry rules] set, with re-entry only on the word of the person the site appoints.
PreventingT510 (2 administrative)
CCV-10Stone dust and explosion barriers maintained in coal mines
Stop a methane ignition growing into a coal dust explosion that travels through the mine, by keeping roadway dust inerted with stone dust to [Stone dust standard], proven by sampling, and keeping explosion barriers in place and loaded as required.
MitigatingC29 (2 administrative)
CCV-11Self-rescuers carried, in service and people able to use them
Make sure everyone underground carries, or has within reach as the site sets, a self-rescuer of the type the site's risk assessment requires, in service and undamaged, and can put it on quickly in the dark.
MitigatingC1, C39 (2 administrative)
CCV-12Refuge chambers and fresh air bases ready
Give people who cannot escape a safe place to wait for rescue, with refuge chambers or fresh air bases where the emergency plan puts them, with breathable air, water, communications and supplies, maintained and accessible.
MitigatingC39 (2 administrative)
CCV-13Gas trigger action response, evacuation and mine rescue
When gas reaches a trigger in [Gas trigger levels], or there is a fire, explosion or ventilation failure, carry out the trigger action response plan: warn everyone, withdraw people to fresh air or out of the mine, account for everyone, and have trained mine rescue ready to respond.
MitigatingC1, C2, C310 (2 administrative)

Threats

  • T1 Not enough air delivered to the workings, people and diesel plant in them
  • T2 A fan stops or the air is short-circuited (doors, stoppings, ducts)
  • T3 Gas builds up: methane, carbon monoxide, hydrogen sulphide or low oxygen
  • T4 An ignition source meets flammable gas or coal dust
  • T5 People enter after firing or a fan stoppage before the air is cleared

Consequences

  • C1 Workers overcome, poisoned or asphyxiated
  • C2 Methane or coal dust explosion, or fire
  • C3 People trapped in smoke or irrespirable air

Supporting controls, shown dashed on the bowtie with no CCV form: Diesel engine maintenance and emissions testing (on T1); Fire prevention on conveyors and mobile plant (on T4); Exposure and health monitoring (on C1); Explosion seals and fire doors (on C2).

How each form is scored

The same rules in every pack. The worst item decides the overall result.

MarkWhen
PassYou saw it in place and working, today. A Pass is something you saw, not something you remembered or were told.
FailIt is not in place, or it does not work, or it is bypassed. On an administrative item, use Fail only when what you found means the control itself is not there (for example, nobody on the shift is authorised to operate).
Non-conformance (NC)Administrative items only. The control is in place and working, but a supporting element is missing, late or incomplete: a record, a training date, a review date. Fix it as an action.

Non-conformance is offered only on administrative items: records, training currency, plan and review dates, things that would not on their own cause the unwanted event straight away. Every other item checks that the control is physically there and working, so it is Pass or Fail only: its NC box is greyed out.

Overall resultWhenWhat happens
PASSEvery item PassIn place and effective. Record it in the CCV schedule, and check it against hazard reports, near misses and incidents for this control.
NON-CONFORMANCENo Fail; one or more NCIn place, not fully effective. A temporary control first if needed; an action for each NC, with an owner, closed within 30 days. Tell the supervisor and control owner this shift. A repeat NC is investigated.
FAILAny item FailNOT effective. Stop the work that relies on it, make it safe, and tell the supervisor and the escalation contact now. Report it as a high potential incident. Restart only when the control, or a temporary control the risk owner accepts, is in place and verified again.

Talk to the people

The fourth page of every form: five or six prompts written for that control. Talk to at least two people who use, maintain or supervise this control, on the job and in their own words. Ask open questions and listen: they know where it gets skipped, worked around or is hard to use.

  • Anything that suggests the control is missing, bypassed or not working is checked in the field straight away and scored; confirmed, it is a Fail.
  • Everything else that matters goes in the comments, and each thing to fix becomes an action with an owner and a due date.
  • The people spoken to are told what will happen with what they said, and it is never used against them.

What is included

Delivered as one ZIP download. The files below are editable, and the Word documents also come as PDFs. Each download also includes Read Me First, a Product Overview, the Permitted Use Terms and Version Information (PDF).

FileFormatWhat it is for
How to Use These CCVsWord (.docx)The guide: what a CCV is, how to verify and score, the response to a Fail or Non-conformance, frequency, and how to adapt the pack to your site.
Mine Gases and Ventilation BowtieWord (.docx)Every threat, consequence and critical control on one landscape page, with its key: which controls prevent, which mitigate, which work on both sides, and the supporting controls.
CCV-01 Ventilation delivers the designed air to every working placeWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-02 Main and booster fans running, monitored and alarmedWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-03 Auxiliary fans and ducting delivering air to the faceWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-04 Ventilation doors, stoppings and regulators intact and setWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-05 Fixed gas monitoring with alarms and power trips acted onWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-06 Personal and portable gas detectors carried, tested and usedWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-07 Gas drainage working where the seam or ground requires itWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-08 Ignition sources controlled where flammable gas or coal dust may be presentWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-09 Re-entry after firing or a fan stoppage only after gas testingWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-10 Stone dust and explosion barriers maintained in coal minesWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-11 Self-rescuers carried, in service and people able to use themWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-12 Refuge chambers and fresh air bases readyWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV-13 Gas trigger action response, evacuation and mine rescueWord (.docx)A four-page field form for one critical control: its bowtie, objective, performance requirements and failure modes, the checklist (Pass, Fail, and Non-conformance on administrative items only), the overall result, actions, talk to the people, and sign-off.
CCV ScheduleWord (.docx)Who verifies each control, how often by exposure, the method and the record: in Word, and as an Excel workbook with suggested frequencies, next due dates and status by formula.
CCV ScheduleExcel (.xlsx)Who verifies each control, how often by exposure, the method and the record: in Word, and as an Excel workbook with suggested frequencies, next due dates and status by formula.

The technical content paraphrases, and cites by title, the mining work health and safety laws and regulations for your state or territory, the mines regulator's guidance on ventilation, air quality, gas monitoring, diesel exhaust and explosion prevention, the model Code of Practice How to manage work health and safety risks, the workplace exposure standards for airborne contaminants, and your ventilation officer's and engineers' advice for the site. Nothing is copied.

Questions about this pack

What is a critical control verification (CCV)?

A planned check, in the field, that one critical control is doing its job: that it exists, is in place and in good condition, functions as designed, is used properly and is not bypassed or failing silently. It is proof, not assumption. It is not a general inspection or audit: it tests one control, in depth, against what it must achieve. A CCV form, or CCV checklist, is the record of that check.

Which critical controls are in the Mine Gases and Ventilation pack?

13 critical controls (9 preventing, 4 mitigating) for the unwanted event: exposure to or ignition of mine gases, or loss of ventilation, underground. CCV-01 Ventilation delivers the designed air to every working place; CCV-02 Main and booster fans running, monitored and alarmed; CCV-03 Auxiliary fans and ducting delivering air to the face; CCV-04 Ventilation doors, stoppings and regulators intact and set; CCV-05 Fixed gas monitoring with alarms and power trips acted on; CCV-06 Personal and portable gas detectors carried, tested and used; CCV-07 Gas drainage working where the seam or ground requires it; CCV-08 Ignition sources controlled where flammable gas or coal dust may be present; CCV-09 Re-entry after firing or a fan stoppage only after gas testing; CCV-10 Stone dust and explosion barriers maintained in coal mines; CCV-11 Self-rescuers carried, in service and people able to use them; CCV-12 Refuge chambers and fresh air bases ready; CCV-13 Gas trigger action response, evacuation and mine rescue.

What is a bowtie, and is it included?

A bowtie is a one-page diagram of a risk: the threats that could cause the unwanted event on the left, the consequences on the right, and the critical controls on each line. The Mine Gases and Ventilation Bowtie is included in Word and PDF, so you can use it as an editable bowtie template for your site, and each CCV form shows where its control sits on it.

How is a CCV scored?

Pass or Fail on every item. Non-conformance is offered only on administrative items: records, training currency, plan and review dates, things that would not on their own cause the unwanted event straight away. Every other item checks that the control is physically there and working, so it is Pass or Fail only: its NC box is greyed out. Any Fail means the control is not effective: the work that relies on it stops, and it is escalated as a high potential incident. A Non-conformance gets a temporary control if needed and an action closed within 30 days; a repeat is investigated.

What is on the last page of each form?

Talk to the people: five or six prompts written for that control, for the operators, workers and supervisors who use it: what they actually do, when it gets skipped or is hard to use, what has changed, and what they would fix. Anything that suggests the control is missing, bypassed or not working is checked in the field straight away and scored; confirmed, it is a Fail. Everything else that matters goes in the comments, and each thing to fix becomes an action with an owner and a due date.

How often should critical controls be verified?

The CCV schedule (verification schedule) sets how often each critical control is verified, by the exposure where it is used: high (daily exposure, many people or vehicles), medium (weekly, or few people) or low (an occasional task). The guide gives weekly, monthly and quarterly as starting points; each control's own frequencies are set in the schedule. Verify a control in every place it is used, in turn, and more often after a Fail, a near miss or a change, and while an action is open.

Is this pack suitable for my state?

Yes, anywhere in Australia, and outside Australia too. Written to work in any country, with Australian law as the worked example: the documents say to check the law, the regulator and the guidance where you work, and in Australia they work in every state and territory, Victoria included. The model Code of Practice How to manage work health and safety risks and other Australian guidance are cited by title as the example. Some requirements, such as licences, notifying the regulator and registering plant, differ between countries and jurisdictions: check with your regulator. In Australia, your state or territory may have approved the codes with changes, and Victoria has its own Occupational Health and Safety Act and regulations, and WorkSafe Victoria publishes its own guidance. In Australia, mining has its own work health and safety laws: each state and territory has laws or regulations for mines and quarries, and your site's principal hazard management plans and trigger action response plans come first. The pack gives no design values: every limit is a placeholder for your site's own design criteria and standards.

Can we change the forms?

Yes. Every form, the bowtie and the schedule are editable Word and Excel files: add your logo and business name, your site's limits, plant and roles, delete items that do not apply and add your own. The guide says what to adapt, and how to decide whether a new item may offer Non-conformance.

Is it legal advice, or the same as an audit?

No. These forms help your business prove that its critical controls are in place and working. They do not do that on their own: adapt them to your site, plant and people, verify in the field, and act on what you find. The forms are general information, not legal advice. Work health and safety law differs between jurisdictions and changes over time. Check the requirements that apply where you operate.

Is GST included in the price?

Yes, for buyers in Australia: every price in the store includes GST, so $149.00 is the total, including $13.55 GST, and your receipt is a tax invoice showing the GST. Buyers outside Australia don't pay GST: you pay $135.45, the price without the GST, and your receipt shows no GST.

How are the files delivered?

As a ZIP download. Card purchases can be downloaded straight away from the confirmation page and by a link we email you. Download links expire after 14 days for security; you can request a new one at any time.

Can we use it at more than one site?

Yes, across your own organisation. The pack is licensed for internal use by the purchasing organisation. A consultant using it with clients needs separate written permission.

What is your refund policy?

Your rights under the Australian Consumer Law are not affected. See the Refund Policy for how we handle a product that is faulty, not as described, or not what you ordered.

Legal information here is general. It may not be correct in your jurisdiction: please check with your local WHS or OHS regulator.

Ordering for a business or several sites? Request an invoice. Other questions: contact us.

Goes with

The plan that sets up the critical risk program these forms verify. The Critical Control Management training packages.

Critical Risk Management Plan

For: Australian businesses with work that could kill or seriously injure someone, and the officers, managers, supervisors and WHS advisers who manage those risks

A complete, editable critical risk management plan for Australian businesses: find the risks that could kill, map them with bowties, define, own and verify the critical controls, aligned to the model WHS laws and ISO 31000.

What's included
  • The critical risk management plan, a policy, and a roles and accountabilities guide with officers' due diligence
  • A broad-brush workshop guide, an Excel critical risk register that tiers and ranks each risk on the same risk matrix as the WHS plans, and a drawn bowtie template
  • A critical control selection checklist, performance standard template, control owner accountability statement and Excel critical controls register
  • An Excel verification program and schedule, a generic verification form scored Pass, Fail or Non-conformance, an officers' report, a failure response procedure and a dashboard
$349incl. GST$317.27AUD, GST-free outside Australia
Add to CartRequest Invoice

Training: Critical Control Management Practitioner · Critical Control Management Implementation Toolkit